力士樂(lè)機(jī)床維修驅(qū)動(dòng)器:E255 Feedrate-Override(S-0-0108) = 0進(jìn)給速率超控(S-0-0108)=0。上海仰光電子科技有限公司專業(yè)從事各品牌伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修,觸摸屏維修,變頻器維修,伺服器維修,伺服控制器維修,數(shù)控系統(tǒng)維修改造,機(jī)器人維修保養(yǎng)以及各種板卡,芯片級(jí)維修維護(hù),免費(fèi)檢測(cè),快速維修,部分立等可取!
博士力士樂(lè)驅(qū)動(dòng)器維修:
Description:說(shuō)明:
The transversing velocity can be changed while jogging, homing and
while in positioning operation with the "S-0-0108, Feedrate Override"
parameter. Since the drive controller cannot follow command values
which do not move, the warning will be given if the value of this parameter
is 0.在慢跑、歸位和使用“S-0-0108,進(jìn)給率超控”進(jìn)行定位操作時(shí)參數(shù)由于驅(qū)動(dòng)器控制器無(wú)法遵循命令值如果此參數(shù)的值為0。
Cause:原因:
1. Feedrate override is set at zero.
進(jìn)給速率超控設(shè)置為零。
2. The "Feedrate Override Via Analog Output" field is activated
and the voltage there is 0V.
激活“通過(guò)模擬輸出的進(jìn)給率超控”字段并且那里的電壓是0V。
3. Positioning speed = 0 定位速度=0
Remedy:解決措施:
1. Set the S-0-0108 parameter to the correct value for the
application.
將S-0-0108參數(shù)設(shè)置為應(yīng)用
2. Deactivate the field or establish a voltage larger than 0V.
停用磁場(chǎng)或建立大于0V的電壓。
3. Positioning speed greater than 0 must be selected.
必須選擇大于0的定位速度。
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://www.btdjy.com/fuwu/Services_Show14189.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
聯(lián)系方式:
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.btdjy.com
【 我們確保修好測(cè)試好給客戶。。!】
上一篇:溫州三菱工控機(jī)主板故障維修怎么聯(lián)系-仰光電子
下一篇:溫州羅克韋爾AB工控機(jī)開(kāi)機(jī)無(wú)顯示故障維修不限型號(hào)