F644 Negative Travel Limit Switch Detected
檢測到負行程限位開關
The negative travel limit switch has been actuated. The axis has been
stopped with the error reaction "set velocity command value to zero". Bit 2
of P-0-0090, Travel limit parameter has been set to "Exceeding the
travel limit is considered as an error", or a drive control command has
been started while the axis limit value is exceeded (e.g. drive-controlled
homing).
負行程限位開關已啟動。軸已經(jīng)以錯誤反應“將速度命令值設置為零”停止。第2位P-00090中,行程限制參數(shù)已設置為“超過行程限制被視為錯誤”,或驅(qū)動控制命令已在超過軸極限值時啟動(例如,驅(qū)動控制歸位)。
Cause:原因:
The negative travel limit switch has been actuated
負行程限位開關已啟動
Remedial action:補救措施:
1. Reset the error
重置錯誤
2. Activate the power supply
激活電源
3. Move the axis into the permissible working range
將軸移動到允許的工作范圍內(nèi)
Note: The drive will not accept any command values that lead further away from the permissible range. Specifying such a command will again result in this error.注意:驅(qū)動器不會接受任何遠離允許范圍的命令值。指定這樣的命令將再次導致此錯誤。